DescriptionThe XR06CX-4N1F1, format 1.26' x 2.91' x 2.36' (32 x 74 x 60 mm), is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost which can be either electrical or reverse cycle (hot gas). The device is also provided with 2 NTC probe inputs, the first one for temperature control and the second one to be located onto the evaporator, to control the defrost termination temperature and to managed the fan and it's provided with a configurable digital input. With the HOTKEY it's possible to program the instrument in a quick and easy way.
Specification
Supply Voltage: 120V/AC
Sensor type: NTC
Buzzer: Yes
Display unit: ℉/℃
Compressor load current: 20A
Operating Temperature: 32~140℉(0~60℃)
Applicable temperature range: -40~210.2℉(-40~99℃)
Product Dimensions: Front 1.26' x 2.91' (32x74 mm);
Mounting dimensions: Opening 2.79' x 1.14'(71x29 mm)
Built-in depth: 2.36' (60 mm)
Medium-low temperature, forced air-cooled, electrically heated or hot air defrost thermostats
Defrost
Two defrost modes are available through the "td " parameter:
td=EL defrost through electrical heater (compressor OFF)
td=in hot gas defrost (compressor ON).
Other parameters are used to control the interval between defrost cycles (id) ), its maximum length (Md) and two defrost modes: timed or controlled by the evaporator's probe. At the end of defrost dripping time is started, its length is set in the dt parameter. With dt=0 the dripping time is disabled.
Instrument and Mounting
Instrument XR06CX-4N1F1 shall be mounted on vertical panel, in a 1.14' x 2.79'(29x71 mm) hole, and fixed using the special bracket supplied. The temperature range allowed for correct operation is 32~140℉(0-60℃). Avoid places subject to strong vibrations, corrosive gases, excessive dirt or humidity. The same recommendations apply to probes. Let air circulate by the cooling holes.
Package List
1*Manual
1*Thermostat Controller
2*Temperature Sensor
2*Special Bracket
Description
Model XR02CX-5N0C1, format 1.26' x 2.91' x 1.97'(32 x 74 x 50 mm), is a digital thermostat with off cycle defrost designed for refrigeration applications at normal temperature. It provides a relay output to drive the compressor. It is also provided with 1 NTC probe input and one configurable digital input. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or the by HOTKEY.
Specification
Supply voltage: 230V/AC
Sensor type: NTC
Buzzer: No
Display unit: ℉/℃
Compressor load current: 20A
Operating Temperature: 32~140℉(0~60℃)
Applicable temperature range: -40~210.2℉(-40~99℃)
Product dimensions: Front 1.26' x 2.91' (32x74 mm);
Mounting dimensions: Opening 2.79' x 1.14'(71x29 mm)
Built-in depth: 1.97' (50mm)
Cooling/Heating/Stop Defrost Type Thermostat
Defrost
Defrost is performed through a simple stop of the compressor. Parameter "id" controls the interval between defrost cycles, while its length is controlled by parameter "Md" .
Instrument and Mounting
The instruments shall be mounted on vertical panel, in a 1.14' x 2.79'(29x71 mm) hole, and fixed using the special bracket supplied. The temperature range allowed for correct operation is 32~140℉(0-60℃). Avoid places subject to strong vibrations, corrosive gases, excessive dirt or humidity. The same recommendations apply to probes. Let air circulate by the cooling holes.
Package List
1*Manual
1*Thermostat Controller
1*Temperature Sensor
2*Special Bracket
Description
The XR03CX-5N0C1, in 1.26" x 2.91" x 1.97" (32x74x50 mm) short format, is microprocessor based controller suitable for applications on normal temperature refrigerating units. It provides two relay output: one for compressor and the other one for alarm signalling or as auxiliary output. It provides an NTC probe input and a digital input for alarm signalling, for switching the auxiliary output or for start defrost. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or the by HOTKEY.
Specification
Supply voltage: 230V/AC
Sensor type: NTC
Buzzer: No
Display unit: ℉/℃
Compressor load current: 20 A
Operating Temperature: 32~140℉(0~60℃)
Applicable temperature range: -40~210.2℉(-40~99℃)
Product dimensions: Front 1.26" x 2.91" (32x74 mm);
Mounting dimensions: Opening 2.79" x 1.14" (71x29 mm)
Built-in depth: 1.97" (50mm)
Normal temperature, stop frost, additional alarm/bank light output type thermostat
Defrost
Defrost is performed through a simple stop of the compressor. Parameter "id" controls the interval between defrost cycles, while its length is controlled by parameter "Md" .
Instrument and Mounting
Instrument XR03CX-5N0C1 shall be mounted on vertical panel, in a 1.14" x 2.79"(29x71 mm) hole, and fixed using the special bracket supplied. The temperature range allowed for correct operation is 32~140℉(0-60℃). Avoid places subject to strong vibrations, corrosive gases, excessive dirt or humidity. The same recommendations apply to probes. Let air circulate by the cooling holes.
Package List
1*Manual
1*Thermostat Controller
1*Temperature Sensor
2*Special Bracket